Downloads
08-09-01: NEW !
TotalPac2 Units with integrated control panel (self-contained) are now provided
with the new Viking VFR-400 Release Control Panel. Furthermore,
the Viking EZ-Trim has been upgraded to Viking's New Conventional Trim.
Although the Viking EZ-Trim & PAR-3 Release Control Panel are no longer be available, replacement parts and
support still are. Contact FireFlex
Product Support department for any enquiries or
click here to access the TotalPac2
Archives.
TotalPac2 Technical Specifications:
This page contains the
standardized technical specifications
available for the TotalPac2 Product Line. Clicking on a
document's name will display a "pdf" file of that document on your browser. You can then view and
/ or print the document as you require.
Clicking on an MSWord
document's name will automatically launch your MS Word application and
display a "doc" file of that document. You can then edit the
document as you require.
NOTICE: Due
to variable job conditions or additional requirements requested by owner
or authorities having jurisdiction these documents are intended as an
information guide only and not as a final project design.
The consulting engineer should make appropriate adjustments for
the project involved.
|
Document No. |
Description
|
MSWord's
.doc format |
Acrobat's
.pdf format |
|
-
PREACTION: |
|
FM-072D-0-74 |
FM-072D-0-74 |
Non Interlocked Pneumatic Release, Remote Controlled |
|
FM-072D-0-73 |
FM-072D-0-73 |
Non Interlocked Electric Release, Remote Controlled |
|
FM-072D-0-72 |
FM-072D-0-72 |
Non
Interlocked Electric Release, Self contained |
|
FM-072D-0-77 |
FM-072D-0-77 |
Single Interlocked
Pneumatic Release, Remote Controlled |
|
FM-072D-0-76 |
FM-072D-0-76 |
Single Interlocked Electric
Release, Remote Controlled |
|
FM-072D-0-75 |
FM-072D-0-75 |
Single Interlocked Electric
Release, Self contained |
|
FM-072D-0-83 |
FM-072D-0-83 |
Single Interlocked Firecycle Release,
Remote Controlled |
|
FM-072D-0-82 |
FM-072D-0-82 |
Single Interlocked Firecycle Release, Self contained |
|
FM-072D-0-96 |
FM-072D-0-96 |
Single Interlocked SureFire
Release, Remote Controlled |
|
FM-072D-0-95 |
FM-072D-0-95 |
Single Interlocked SureFire
Release, Self contained |
|
FM-072D-0-81 |
FM-072D-0-81 |
Double Interlocked Pneumatic Release, Remote Controlled |
|
FM-072D-0-79 |
FM-072D-0-79 |
Double
Interlocked Electric-Pneulectric Release, Remote Controlled |
|
FM-072D-0-78 |
FM-072D-0-78 |
Double Interlocked Electric-Pneulectric Release, Self contained |
|
FM-072D-0-103 |
FM-072D-0-103 |
Double Interlocked
Electric-Pneumatic Release, Remote Controlled |
|
FM-072D-0-80 |
FM-072D-0-80 |
Double Interlocked Electric-Pneumatic Release, Self contained |
|
FM-072D-0-85 |
FM-072D-0-85 |
Double Interlocked
Firecycle Release, Remote Controlled |
|
FM-072D-0-84 |
FM-072D-0-84 |
Double Interlocked
Firecycle Release, Self contained |
|
FM-072D-0-98 |
FM-072D-0-98 |
Double Interlocked SureFire Release, Remote Controlled |
|
FM-072D-0-97 |
FM-072D-0-97 |
Double Interlocked SureFire Release, Self contained |
|
- DELUGE: |
|
FM-072D-0-88 |
FM-072D-0-88 |
Pneumatic Release, Remote Controlled |
|
FM-072D-0-89 |
FM-072D-0-89 |
Hydraulic
Release, Remote Controlled |
|
FM-072D-0-87 |
FM-072D-0-87 |
Electric
Release, Remote Controlled |
|
FM-072D-0-86 |
FM-072D-0-86 |
Electric
Release, Self contained |
|
FM-072D-0-91 |
FM-072D-0-91 |
Firecycle
Release,
Remote Controlled |
|
FM-072D-0-90 |
FM-072D-0-90 |
Firecycle
Release, Self contained |
|
- DRY PIPE: |
|
FM-072D-0-99 |
FM-072D-0-99 |
Standard Pressure, Remote Controlled |
|
FM-072D-0-92 |
FM-072D-0-92 |
High-Pressure
(HP), Remote Controlled |
|
- WET PIPE: |
|
FM-072D-0-100 |
FM-072D-0-100 |
Constant Pressure, Remote Controlled |
|
FM-072D-0-101 |
FM-072D-0-101 |
With
Retard
Chamber, Remote Controlled |
|
FM-072D-0-102 |
FM-072D-0-102 |
With
Excess Pressure
Pump, Remote Controlled |
|
FM-072D-0-94 |
FM-072D-0-94 |
Firecycle
Release, Remote Controlled |
|
FM-072D-0-93 |
FM-072D-0-93 |
Firecycle
Release, Self contained |
 |
Note: Acrobat Reader® version
4.0 or above is required on your computer to view the
various documents. If you do not have this useful utility
installed on your computer, simply click on the logo to
download a free version.
For additional instructions regarding the use of Acrobat's 'pdf'
files,
click here. |
|
 
 |
Viking TotalPac2:
Integrated sprinkler systems cabinets |
|